Platform · Water mitigation

A drying file that holds up on desk review.

Every reading, photo and equipment day is tied to a room, a point and a time. Before a report or invoice leaves the shop, preflight catches what an adjuster would cut.

Fictional demo · final drying report preflight
Dry standard on every point
Pass
Daily readings while equipment on site
Pass
Dehumidifier billed 1 day after goals met
Block
Flat readings at point 4 for 2 days
Warn
3 photos still waiting to sync
Block

Tools for your team

Sketch and moisture map

Draw rooms on the phone or scan them with LiDAR, group them into chambers, and pin moisture points against unaffected dry standards.

Category and class

Set per chamber before equipment goes in. Every change keeps who made it, when and why.

Psychrometrics

Temperature and RH give GPP and dew point. Pressure is estimated from elevation and labeled that way.

Readings with their meter

Meter, mode, scale and depth on every reading. Snap the meter screen and the tech confirms the value, or type it in.

Equipment sizing

Air movers and dehumidifiers sized with the published S500 calculations. Placing outside the range asks for a written reason.

Honest goals

Dry means every active point is at or below its goal. A point can't be deleted to make a job pass.

Preflight

Fix it before the adjuster finds it.

Preflight runs on the final report, photo package and invoice. Some gaps block delivery until they're fixed; others need a signed note explaining them, which prints in the report.

Preflight checks your file. It doesn't promise what a carrier will pay.

CheckResult
Missing dry standard or mismatched meter scaleBlocks
Equipment on site with no readings that dayBlocks
Equipment billed after goals were metBlocks
Photos or forms not yet syncedBlocks
Sizing outside the recommendationNeeds a reason
Flat readings for two daysWarns
Late entriesWarns, times shown

Reports with your name on them

  • Drying log
  • Moisture map
  • Equipment log
  • Photo report
  • Signed forms
  • Certificate of completion
  • Captioned photo ZIP

Branded with your company, built from one locked snapshot of the job, and showing original values alongside any corrections.

Questions

Which standard do the calculations follow?

The published calculations in ANSI/IICRC S500 (5th edition). The version is saved with every calculation.

Do you support Bluetooth meters?

Enter readings with the meter, mode, scale and depth used on the job. You do not need a Bluetooth meter to document readings; Bluetooth meter sync is not included.

Does a clean preflight mean I'll get paid in full?

No. It means your file is complete and consistent. What gets paid is still the carrier's decision.

Included in every plan, with every other module.